About Us
Activities
COGERATION
GENERATION
CLIMATIZATION: ABSORPTION AND COMPRESSION
PRODUCTION OF CHILLED WATER AND STEAM, THROUGH HEAT RECOVERY, BIOGAS, NATURAL GAS
BIOGAS: POWER GENERATION AND TREATMENT
OPERATION & MAINTENANCE AND TECHNICAL ASSISTENCE (OEM)
OTHERS AREAS OF EXPERTISE
Clients
Contact
Catalog
News
COGERATION
COCA-COLA
ITABIRITO - MG
COGENERATION 5.250 ekW / 4.350 kg/h steam production
More details
SÃO PAULO CORPORATE TOWERS
SÃO PAULO - SP
COGENERATION: 6.165 ekW / 730 RT
More details
ROCHAVERÁ CORPORATE TOWERS
SÃO PAULO - SP
COGENERATION 8.200 ekW / 4.770 RT
More details
SÃO PAULO EXPO EXHIBITION & CONVETION CENTER
SÃO PAULO - SP
COGENERATION: 5.973 ekW / 5.235 RT
More details
SHOPPING NOVA IGUAÇU
NOVA IGUAÇU - RJ
COGENERATION: 2.852 ekW / 1.790 RT
More details
PLAZA IGUATEMI BUSINESS CENTER
SÃO PAULO - SP
COGENERATION: 2.736 ekW / 600 RT
More details
GRAND MERCURE HOTEL
SÃO PAULO - SP
COGENERATION: 300 ekW / 100 RT / 153 kW hot water production
More details
INAPEL
GUARULHOS - SP
COGENERATION: 1.120 ekW / 5.000 kg/h steam production / 176 RT
More details
MERCEDES BENZ
IRACEMÁPOLIS - SP
COGENERATION: 2.702 ekW / 1.500 RT / 3.000 kW HOT WATER PRODUCTION
More details
PIRAQUÊ TURIAÇU
RIO DE JANEIRO - RJ
COGENERATION: 4.000 EKW / 1.074 TR / 2.300 KG/H STEAM PRODUCTION
MOTOGENERATORS: 2 X 2.000 EKW NG
HOT WATER ABSORPTION CHILLERS: 2 X 250 RT
HEAT RECOVERY STEAM GENERATOR: 2 X 1.150 KG/H
CENTRIFUGAL CHILLERS: 2 X 287 RT
CENTERVALE SHOPPING
SÃO JOSÉ DOS CAMPOS - SP
COGENERATION: 2.000 EKW / 2.070 RT
MOTOGENERATOR: 2.000 EKW NG
HOT WATER ABSORPTION CHILLER: 590 RT
DIRECT FIRED ABSORPTION CHILLER: 630 RT
CENTRIFUGAL CHILLER: 860 RT
CAXIAS SHOPPING
DUQUE DE CAXIAS - RJ
COGENERATION E EMERGENCY BACK UP: 1.300 EKW / 1.168 RT
MOTOGENERATOR: 1.300 EKW NG
EMERGENCY BACK UP: 725 EKW
HOT WATER ABSORPTION CHILLER: 368 RT
DIRECT FIRED ABSORPTION CHILLER: 500 RT
CENTRIFUGAL CHILLER: 300 RT
PARQUE DAS BANDEIRAS SHOPPING
CAMPINAS - SP
COGENERATION: 2.000 EKW / 2.070 RT
MOTOGENERATORS: 2.000 EKW NG + 1.300 EKW NG
EMERGENCY BACK UP: 800 EKW
HOT WATER ABSORPTION CHILLER: 590 RT
DIRECT FIRED ABSORPTION CHILLER: 630 RT
CENTRIFUGAL CHILLER: 850 RT
SHOPPING TABOÃO
TABOÃO DA SERRA - SP
COGENERATION: 3.300 EKW / 792 RT
MOTOGENERATOR:2.000 EKW NG + 1.300 EKW NG
HOT WATER ABSORPTION CHILLER: 792 RT
SHOPPING BONSUCESSO
GUARULHOS - SP
COGENERATION: 1.300 EKW / 510 RT
MOTOGENERATOR: 1.300 EKW NG
HOT WATER ABSORPTION CHILLER: 360 RT
DIRECT FIRED ABSORPTION CHILLER: 150 RT
SHOPPING INTERLAGOS
SÃO PAULO - SP
COGENERATION: 1.750 EKW / 1.308 RT
MOTOGENERATOR: 1.750 EKW NG
HOT WATER ABSORPTION CHILLER: 748 RT
DIRECT FIRED ABSORPTION CHILLER: 560 RT
SHOPPING CAMPO GRANDE
CAMPO GRANDE - MS
COGENERATION: 2.600 EKW / 640 RT
MOTOGENERATORS: 2X1.300 EKW NG
HOT WATER ABSORPTION CHILLER: 640 RT
PIRAQUÊ QUEIMADOS
QUEIMADOS - RJ
COGENERATION: 2.000 EKW / 250 RT / 1.150 KG/H STEAM PRODUCTION
MOTOGENERATOR: 2.000 EKW NG
HOT WATER ABSORPTION CHILLER: 250 RT
HEAT RECOVERY STEAM GENERATOR: 1.150 KG/H
LEVORIN
GUARULHOS - SP
COGENERATION: 4.000 EKW / 12.000 KG/H STEAM PRODUCTION
MOTOGENERATORS: 2 X 2.000 EKW NG
HEAT RECOVERY STEAM GENERATOR WITH SUPPLEMENTARY BURNING:12.000 KG/H @ 16,5 BARG
AHLSTROM
LOUVEIRA - SP
COGENERATION:1.250 EKW / 3.500 KG/H STEAM PRODUCTION
MOTOGENERATOR: 1.250 EKW NG
HEAT RECOVERY STEAM GENERATOR WITH SUPPLEMENTARY BURNING: 3.500 KG/H @ 10 BARG